Installation Instructions
for your new undercounter
TRASH MASHER@ COMPACTOR
BEFORE YOU USE YOUR COMPACTOR . . .
Be sure your compactor IS properly Installed In an appropriate level area and a place suitable for the size.
function and protection of the compactor
ELECTRICAL REQUIREMENTS
Observe All Governing Codes and Ordinances
A 120.Volt. 60 Hz, AC only, 15.Ampere fused electrtcal supply IS required (Time delay fuse or circuit breaker IS
recommended ) It IS recommended that a separate clrcult serving only this appliance be provided DO NOT use
an extension cord
RECOMMENDED GROUNDING METHOD
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD
3-PRONG
GROUND PRONG.
CROUNOlNC TYPE
WALL RECEPTACLE
For your personal safety, this appliance must be grounded
‘1
This appliance IS equipped with a power supply cord
having a 3-prong grounding plug To mlnlmlze possible
shock hazard, the cord must be plugged Into a mating 3-
prong grounding type wall receptacle, grounded In
accordance with the National ElectrIcal Code and local
codes and ordinances If a mating wall receptacle
IS
not
avallable, It
IS
the personal responslblllty and obllgatlon of
- POWER SUPPLY
the customer to have a properly grounded 3-prong wall
receptacle Installed by a quaIlfled electrlclan See Figure 1
FIGURE I
ALTERNATE GROUNDING METHOD
(Do
not use
in Canada)
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORR
GROUND PRONG.
If changing and properly grounding the wall receptacle IS
lmposstble and where local codes permit (constrlt your
electrlcal Inspector), a temporary adapter may be plugged
into the exlstlng 2-prong wall receptacle to mate with the
3-prong power supply cord See fjgure 2 THIS,
HOWEVER, IS NOT RECOMMENDED
If this
IS
done, you must connect the grounding eyelet on
the adapter to the wall receptacle coverplate screw and
from this same screw you must connect a separate copper
ground wire (No 18 mlnlmum) to a grounded cold water
pipe
l
See Figure 2. Do not ground to a gas supply pipe. Do
not connect to electrical supply until appliance Is
permanently grounded
ASSEMBLY
GROUND ASSEMBLY
(AllACH TO GROUNDED
COLO WATER PIPE)
G
FIGURE 2
WALL RECEPTACLE
IEO
METER9
NO. 4 COPPER - f
WIRE
2,
1
\<
./”
P
CLAMPS
PETAL WATER PIPE
-MPORTANT-
DO NOT REMOVE THIS JNSTRUCTION
SHEET CINTIL READY FOR INSTALLATION.
AFTER
COMPlETlNC 7HE INSTALLATION, SAVE THESE INSTRUCTIONS FOR FUTURE USE.