Whirlpool PN 642 /I (OW) Istruzioni per l'uso Pagina 6

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 6
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 5
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: if the distance “A” between the wall cabinets is between
600 mm and 680 mm, the height “B” must be a minimum of 520 mm.
if the distance “A” between the wall cabinets is greater than the width
of the hob, the height “B” must be a minimum of 400 mm.
In case of installation of a hood above the hob, please refer to the hood
instructions fot the correct distance.
Type of gas
used
Rated thermal
ow rate
Rated
consuption
Reduced heat
capacity
Gas pressure
mbar
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Model conguration
4 BURNERS
Air required (m) for
burning 1 m of gas
ELECTRIC SUPPLY: 220-240 V ~ 50/60 Hz
Rapid
Semi-rapid
Auxiliary
Rapid
Semi-rapid
Auxiliary
Rapid
Semi-rapid
Auxiliary
129 B
97
74 B
86
65
50
86
65
50
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
9.52
30.94
23.80
7.30
7.30
7.30
1R - 2SR - 1AUX
1R - 2SR - 1AUX
1R - 2SR - 1AUX
G20 20 mbar
G30 28-30 mbar
G31 37 mbar
695 l/h
531 g/h
521 g/h
LIQUEFIED
PETROLEUM GAS
(Propane) G31
NATURAL GAS
(Methane) G20
Type of
burner
Injector
marking
kW kW min. rat. max.
17
20
25
20
28-30
37
25
35
45
Type of gas
used
Rated thermal
ow rate (kW)
Total rated
consuption
INJECTORC TABLE CATEGORY II2H3+
Vedere la pagina 5
1 2 3 4 5 6

Commenti su questo manuale

Nessun commento