ASSEMBLY
To secure the hob, use the brackets provided with it. Fit the brackets into the relevant bores shown by the arrow and fasten them by means of their screws in accordance
ADJUSTMENT TO DIFFERENT TYPES OF GAS
If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and information label on the top of the hob, change the injectors.
Remove the information label and keep it with the instructions booklet.
•
•
• Adjust the minimum setting of the taps.
if found to be faulty.
• Remove grids (A).
• B).
• Using a socket spanner of the appropriate size unscrew the injector (C), unscrew the injector to
be replaced.
• Replace it with the injector suitable for the new type of gas.
• Re-assemble the injector in (D).
• If you have a multiple crown burner use side spanner to replace the injector (E).
ADJUSTING MINIMUM GAS SETTING OF TAPS
To ensure that the minimum setting is correctly adjusted, remove the knob and proceed as follows:
•
•
.
• The primary air of the burners does not need to be adjusted.
• to minimum position
REFERENCE TO LOCAL REGULATIONS
Provision for ventilation
The room in which the appliance is installed must have an air supply to current B.S. 5440 - Part 2 standards.
All rooms require a permanent vent in addition to the openable window.
If there are other fuel burning appliances in the same room B.S. 5440 - Part 2 should be consulted to determine the air vent requirements.
If the appliance is installed in a cellar or basement, it is advisable to provide an air vent of 65 cm, irrespective of the room volume.
The law requires that all gas appliances are installed by competent persons in accordance with the current gas safety regulations. Failure to install appliances correctly
may lead to prosecution. It is in your own interest, and that of safety, to ensure that the law is complied with. The hob should be installed in accordance with the
, the
In the G.B., CORGI registered installers work to safe standards of practice.