DIAGNOSTIC GUIDE
Before servicing, check the following:
Make sure there is power at the wall outlet.
Has a household fuse blown or circuit breaker
tripped?Was a regular fuse used? Use a time-
delay fuse.
Is dryer vent properly installed and clear of lint
or other obstructions?
All tests/checks should be made with
a VOM (volt-ohm-milliammeter) or DVM
(digital-voltmeter) having a sensitivity
of 20,000 per volt DC or greater.
Check all connections before replacing
components. Look for broken or loose wires,
failed terminals,or wires not pressed into
connectors far enough.
A potential cause of a controlnot functioning is
corrosion on connections.Observe connections
and check for continuity with an ohmmeter.
Connectors: Look at top of connector. Check
for broken or loose wires. Check for wires not
pressed into connector far enough to engage
metal barbs.
Resistance checks must be made with dryer
unplugged or power disconnected.
DIAGNOSTIC TESTS
These tests allow factory or service personnel
to test and verify all inputs to the machine control
electronics.You may want to do a quick and
overall checkup of the dryer with these tests
before going to specific troubleshooting tests.
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY
PART NO. W10298850A PAGE 1
IMPORTANT
Electrostatic Discharge (ESD)
Sensitive Electronics
ESD problems are present everywhere. ESD may damage or weaken the
machine control electronics.The new control assembly may appear to work well
after repair is finished, but failure may occur at a later date due to ESD stress.
Use an anti-static wrist strap. Connect wrist strap to green ground
connection point or unpainted metal in the appliance.
-OR-
Touch your finger repeatedly to a green ground connection point or
unpainted metal in the appliance.
Before removing the part from its package, touch the anti-static bag
to a green ground connection point or unpainted metal in the appliance.
Avoid touching electronic parts or terminal contacts; handle electronic
control assembly by edges only.
When repackaging failed machine control electronics in anti-static bag,
observe above instructions.
Vedere la pagina 0
1 2 3 4 5 6 ... 55 56

Sommario

Pagina 1 - IMPORTANT

DIAGNOSTIC GUIDEBefore servicing, check the following: Make sure there is power at the wall outlet. Has a household fuse blown or circuit breakertripp

Pagina 2 - 8:88 will be

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 10TROUBLESHOOTING GUIDE Some tests will require accessing components.Problem Possible Cause

Pagina 3 - DEACTIVATING THE DIAGNOSTIC

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 11TROUBLESHOOTING TESTSNOTE: These checks are done with the dryerunplugged or disconnected

Pagina 4

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 124. With an ohmmeter, check the continuity fromL1 and N plug terminals of the power cord t

Pagina 5

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 136. In a similar way, check the continuity betweenthe L1 terminal of the plug and P9-2 (bl

Pagina 6

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 146. Remove the bare copper wire terminal frompin 5 of black drive motor switch. See figure

Pagina 7 - LOAD TEST

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 15Replace the heater if it is electrically open.Replace both the thermal cut-off and high

Pagina 8 - DISPLAY FAULT/ERROR CODES

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 16TEST #4a ThermistorsOutlet ThermistorThe machine control electronics monitors theexhaust

Pagina 9

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 17Inlet Thermistor (Amana ElectricModels Only)The machine control electronics monitors thei

Pagina 10

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 18TEST #4d Gas Valve, Gas Dryer1. Unplug dryer or disconnect power.2. Access the gas valve

Pagina 11 - TEST #1 Supply Connections

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 197. Measurethe resistanceacross eachof the outermost contacts and thecenter terminal (grou

Pagina 12 - P/N XXXXXX Rev X

ACTIVATING THE DIAGNOSTICTEST MODEFOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 21. Be sure the dryer is in standby mode(plugged in with

Pagina 13 - TEST #3 Motor Circuit

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 202. Plug in dryer or reconnect power.3. Perform steps under DIAGNOSTIC: ConsoleButtons and

Pagina 14 - TEST #4 Heater

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 218. If water is still not dispensed:Unplug dryer or disconnect power.Replace the machine

Pagina 15

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 222. Remove the screw that fastens the assemblyto the machine control mounting bracket (fig

Pagina 16 - TEST #4a Thermistors

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 236. The console electronics is split into twoassemblies connected by two cables. Eachassem

Pagina 17 - TEST #4c Thermal Cut-Off

1M 2M 3M 5M 6M=ContactsFunctionStartRunContacts closedBlack-WhiteLt. BlueGreen-YellowRedRedBlackBlueBlueWWHHIITTEEWhiteWhiteCentrifugal Switch (Motor)

Pagina 18 - TEST #5 Moisture Sensor

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 25P8-2GNDRCENTRIFUGALSWITCH2M1M5M6M3MR – LINE L2WDOORSWITCHW – NEUTRAL NTLBULBUWP8-4P8-3P9-

Pagina 19 - Customer-Focused Drying Modes

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 26P8-2GNDL1 LINE – BKBKLBUP8-4P8-3P9-1P8-5DOORNEUTRALMOTORMTR CSMOIST.MOIST RTNMODELMODEL R

Pagina 20 - (Steam Models Only)

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 27P8-22M1M5M6M3MT TANLBUBU CLW BLP8-4P8-3P9-1P8-5BK-W N-BL4MMTR CSMTR CCP13-1P13-2P4-4P4-5P

Pagina 21 - ELECTRONIC ASSEMBLIES

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 281V21IG IGR50–50034 5FS1FS2HOLDRRVALVE NO. 1IGNITORVALVE NO. 2FLAME SENSORÉLECTROV.N 1oÉLE

Pagina 22 - MADE IN COO

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 29GUIDE DE DIAGNOSTICAvant d’entreprendre un travail de réparation,vérifier ce qui suit

Pagina 23

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 3DIAGNOSTIC: Door SwitchOpening the door should cause a beep and analphanumeric number (suc

Pagina 24 - Gas Valve, Gas Dryer

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 30 La corrosion des piècesde connexion est unecause potentielle d’anomalie de fonctionne

Pagina 25 - WIRING DIAGRAM (U.S.)

DIAGNOSTIC : Témoins et boutonsde la consoleDes pressions sur les boutons et la rotation dusélecteur de programme provoquent l’extinctiondes témoins c

Pagina 26

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 32DIAGNOSTIC : Affichage de la tensiond’alimentationUtilisation pour l’affichage de la t

Pagina 27 - ÉLECTRONIQUE DE LA MACHINE

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 33Figure 1a. Diagnostic de la console.Le bouton Controls Lock/Unlock(verrouillage/déverr

Pagina 28

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 34Figure 1b. Diagnostic de la console.Commande sonpropre indicateur.Commande sonpropre i

Pagina 29

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 35ACTIVATION DU TEST -CHARGE MANUELLE1. Veiller à placer la sécheuse au mode d’attente(m

Pagina 30 - DE DIAGNOSTIC

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 36CODES D’ANOMALIE/ERREURLes codes d’anomalie ci-dessous sont normalement affichés lors

Pagina 31

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 37Affichage Description Explications et opérations recommandéesf:26 Défaillance du systè

Pagina 32 - DÉSACTIVATION DU MODE TEST

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 38GUIDE DE DÉPANNAGE Certains tests nécessitent l’accès aux composants.Problème Cause po

Pagina 33

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 39TESTS DE DÉPANNAGENOTE : La sécheuse doit être débranchéeou déconnectée de la source d

Pagina 34

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 4Rotating this CycleSelector turns cycleLEDs on or off.Start button controls its own indica

Pagina 35 - DÉSACTIVATION DU TEST

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 403. Vérifier que le cordon d’alimentation estcorrectement raccordé au câblage de laséch

Pagina 36 - CODES D’ANOMALIE/ERREUR

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 413. Débrancher la sécheuse ou déconnecterla source de courant électrique.4. Remplacer l

Pagina 37

7. Consulter la figure 8, page 41.Mesurer lesvaleurs de résistance des bobinages du moteur(bobinage principal et bobinage de démarrage).Voir le tablea

Pagina 38

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 43Si la résistance est d’environ 10 Ω, passerà l’étape 5.S’il y a un circuit ouvert, p

Pagina 39 - 1 Connexions d’alimentation

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 44Impossibilité d’arrêt du chauffage :1. Débrancher la sécheuse ou déconnecterla source

Pagina 40 - 2 Module de commande de

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 45RÉSISTANCE DE LA THERMISTANCEDU CIRCUIT DE DÉCHARGETemp Résistance Temp Résistance°C (

Pagina 41 - 3 Circuits du moteur

3. Identifier les deux rubans métalliques ducapteur d’humidité à l’avant du logement dutamis à charpie. Établir une liaison entre cesdeux rubans métal

Pagina 42 - 4 Système de chauffage

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 47TEST No5a Réglage pour les modesde séchage centrés sur le clientNOTE : Si le client se

Pagina 43

Pas d’émission de signal sonore :1. Exécuter les étapes de Modulesélectroniques – Accès et dépose, page 49,et vérifier visuellement que le connecteur

Pagina 44 - 4a Thermistances

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 49S’il n’y pas d’injection d’eau dans le tambour :1. Exécuter les étapes du processus Mo

Pagina 45

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 5Figure 1b. Console Diagnostics.Control Lock button operates its own indicator,and Check Li

Pagina 46

Module de commande électroniquede la machine1. Exécuter les étapes 1 et 2 ci-dessus,puis ôterles deux vis de fixation de la bride des circuitsélectron

Pagina 47 - 6 Boutons et témoins

P9151P14P231161183P5P31P131P/N XXXXXX Rev XDate Code YDDD-xxXXXX-XXXMADE IN COOP4P8Figure 18. Module de commande électronique de la machine.N.O.NoirN.

Pagina 48 - DU TAMBOUR

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 521M 2M 3M 5M 6M=ContactsFonctionDémarrageFonctionnementContacts fermésNoir-blancBleu cl

Pagina 49 - ACCÈS ET DÉPOSE

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 53P8-22M1M5M6M3MT TANLBUBU CLW BLP8-4P8-3P9-1P8-5BK-W N-BL4MMTR CSMTR CCP13-1P13-2P4-4P4

Pagina 50

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 541V21IG IGR50–50034 5FS1FS2HOLDRRVALVE NO. 1IGNITORVALVE NO. 2FLAME SENSORÉLECTROV.N 1o

Pagina 51

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 55

Pagina 52 - Contacteur du moteur

POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 56 10/09

Pagina 53

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 6Each buttoncontrols its ownindicator light.Each buttoncontrols its ownindicator light.Turn

Pagina 54

ACTIVATING THE MANUAL LOAD TESTFOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 71. Be sure the dryer is in standby mode (pluggedin with all

Pagina 55

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 8DISPLAY FAULT/ERROR CODESThe fault codes below would be indicated when attempting to start

Pagina 56 - PAGE 56 10/09

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 9Display Description Explanation/Recommended Proceduref:25 Inlet Thermistor Shorted F:25 fl