DIAGNOSTIC GUIDEBefore servicing, check the following: Make sure there is power at the wall outlet. Has a household fuse blown or circuit breakertripp
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 10TROUBLESHOOTING GUIDE Some tests will require accessing components.Problem Possible Cause
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 11TROUBLESHOOTING TESTSNOTE: These checks are done with the dryerunplugged or disconnected
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 124. With an ohmmeter, check the continuity fromL1 and N plug terminals of the power cord t
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 136. In a similar way, check the continuity betweenthe L1 terminal of the plug and P9-2 (bl
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 146. Remove the bare copper wire terminal frompin 5 of black drive motor switch. See figure
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 15Replace the heater if it is electrically open.Replace both the thermal cut-off and high
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 16TEST #4a ThermistorsOutlet ThermistorThe machine control electronics monitors theexhaust
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 17Inlet Thermistor (Amana ElectricModels Only)The machine control electronics monitors thei
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 18TEST #4d Gas Valve, Gas Dryer1. Unplug dryer or disconnect power.2. Access the gas valve
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 197. Measurethe resistanceacross eachof the outermost contacts and thecenter terminal (grou
ACTIVATING THE DIAGNOSTICTEST MODEFOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 21. Be sure the dryer is in standby mode(plugged in with
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 202. Plug in dryer or reconnect power.3. Perform steps under DIAGNOSTIC: ConsoleButtons and
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 218. If water is still not dispensed:Unplug dryer or disconnect power.Replace the machine
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 222. Remove the screw that fastens the assemblyto the machine control mounting bracket (fig
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 236. The console electronics is split into twoassemblies connected by two cables. Eachassem
1M 2M 3M 5M 6M=ContactsFunctionStartRunContacts closedBlack-WhiteLt. BlueGreen-YellowRedRedBlackBlueBlueWWHHIITTEEWhiteWhiteCentrifugal Switch (Motor)
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 25P8-2GNDRCENTRIFUGALSWITCH2M1M5M6M3MR – LINE L2WDOORSWITCHW – NEUTRAL NTLBULBUWP8-4P8-3P9-
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 26P8-2GNDL1 LINE – BKBKLBUP8-4P8-3P9-1P8-5DOORNEUTRALMOTORMTR CSMOIST.MOIST RTNMODELMODEL R
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 27P8-22M1M5M6M3MT TANLBUBU CLW BLP8-4P8-3P9-1P8-5BK-W N-BL4MMTR CSMTR CCP13-1P13-2P4-4P4-5P
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 281V21IG IGR50–50034 5FS1FS2HOLDRRVALVE NO. 1IGNITORVALVE NO. 2FLAME SENSORÉLECTROV.N 1oÉLE
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 29GUIDE DE DIAGNOSTICAvant d’entreprendre un travail de réparation,vérifier ce qui suit
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 3DIAGNOSTIC: Door SwitchOpening the door should cause a beep and analphanumeric number (suc
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 30 La corrosion des piècesde connexion est unecause potentielle d’anomalie de fonctionne
DIAGNOSTIC : Témoins et boutonsde la consoleDes pressions sur les boutons et la rotation dusélecteur de programme provoquent l’extinctiondes témoins c
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 32DIAGNOSTIC : Affichage de la tensiond’alimentationUtilisation pour l’affichage de la t
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 33Figure 1a. Diagnostic de la console.Le bouton Controls Lock/Unlock(verrouillage/déverr
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 34Figure 1b. Diagnostic de la console.Commande sonpropre indicateur.Commande sonpropre i
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 35ACTIVATION DU TEST -CHARGE MANUELLE1. Veiller à placer la sécheuse au mode d’attente(m
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 36CODES D’ANOMALIE/ERREURLes codes d’anomalie ci-dessous sont normalement affichés lors
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 37Affichage Description Explications et opérations recommandéesf:26 Défaillance du systè
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 38GUIDE DE DÉPANNAGE Certains tests nécessitent l’accès aux composants.Problème Cause po
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 39TESTS DE DÉPANNAGENOTE : La sécheuse doit être débranchéeou déconnectée de la source d
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 4Rotating this CycleSelector turns cycleLEDs on or off.Start button controls its own indica
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 403. Vérifier que le cordon d’alimentation estcorrectement raccordé au câblage de laséch
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 413. Débrancher la sécheuse ou déconnecterla source de courant électrique.4. Remplacer l
7. Consulter la figure 8, page 41.Mesurer lesvaleurs de résistance des bobinages du moteur(bobinage principal et bobinage de démarrage).Voir le tablea
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 43Si la résistance est d’environ 10 Ω, passerà l’étape 5.S’il y a un circuit ouvert, p
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 44Impossibilité d’arrêt du chauffage :1. Débrancher la sécheuse ou déconnecterla source
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 45RÉSISTANCE DE LA THERMISTANCEDU CIRCUIT DE DÉCHARGETemp Résistance Temp Résistance°C (
3. Identifier les deux rubans métalliques ducapteur d’humidité à l’avant du logement dutamis à charpie. Établir une liaison entre cesdeux rubans métal
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 47TEST No5a Réglage pour les modesde séchage centrés sur le clientNOTE : Si le client se
Pas d’émission de signal sonore :1. Exécuter les étapes de Modulesélectroniques – Accès et dépose, page 49,et vérifier visuellement que le connecteur
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 49S’il n’y pas d’injection d’eau dans le tambour :1. Exécuter les étapes du processus Mo
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 5Figure 1b. Console Diagnostics.Control Lock button operates its own indicator,and Check Li
Module de commande électroniquede la machine1. Exécuter les étapes 1 et 2 ci-dessus,puis ôterles deux vis de fixation de la bride des circuitsélectron
P9151P14P231161183P5P31P131P/N XXXXXX Rev XDate Code YDDD-xxXXXX-XXXMADE IN COOP4P8Figure 18. Module de commande électronique de la machine.N.O.NoirN.
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 521M 2M 3M 5M 6M=ContactsFonctionDémarrageFonctionnementContacts fermésNoir-blancBleu cl
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 53P8-22M1M5M6M3MT TANLBUBU CLW BLP8-4P8-3P9-1P8-5BK-W N-BL4MMTR CSMTR CCP13-1P13-2P4-4P4
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 541V21IG IGR50–50034 5FS1FS2HOLDRRVALVE NO. 1IGNITORVALVE NO. 2FLAME SENSORÉLECTROV.N 1o
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 55
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIREPAGE 56 10/09
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 6Each buttoncontrols its ownindicator light.Each buttoncontrols its ownindicator light.Turn
ACTIVATING THE MANUAL LOAD TESTFOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 71. Be sure the dryer is in standby mode (pluggedin with all
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 8DISPLAY FAULT/ERROR CODESThe fault codes below would be indicated when attempting to start
FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROYPAGE 9Display Description Explanation/Recommended Proceduref:25 Inlet Thermistor Shorted F:25 fl
Commenti su questo manuale